Suitable service units to
Select ISO classes
ISO classes for compressed air quality:
Which compressed air quality is needed for which application, and which products are suitable?
The links take you to the respective preconfigured service unit.
For larger flow rates, individual components MS12 are available. Please ask your sales engineer for the ideal combination.
| Air conditioning | ISO class | Application | Flow rate [l/min] and suitable service units |
|---|---|---|---|
|
Water separators
|
[-:7:-] |
Applications with condensation-free compressed air Without particle filtration |
|
|
40μm filter
|
[7:4:4] |
Operating medium for
Secondary packaging |
|
|
Filter [μm]: 5
|
[6:4:4] |
|
|
|
Filter [μm]: 5 + 1
|
[2:4:3] |
Applications with a residual oil content < 0.5 mg/m³
|
|
|
Filter [μm]: 5 + 0,01
|
[1:4:2] |
Applications with a residual oil content < 0.01 mg/m
|
|
|
Filter [μm]: 5 + 0.01 + activated carbon filter LFX
|
[1:4:1] |
applications with a residual oil content <0.003 mg/m³, reduction of oil vapours and odours
|
|
|
Filter [μm]: 5 + 0.01 + activated carbon filter LFX + membrane air dryer LDM1
|
[1:3:1] |
|
|
|
Filter [μm]: 5 + adsorption dryer PDAD
|
[2:2:1] |
Applications in the low temperature range
|