Title:
Circuits Safety Subfunctions Pneumatics
Subtitle:
SDE, cat. 1, PL c; PUS, cat. 3, PL e; CH 1: 3/2 closed, positive overlap, monitoring by pressure switch CH 2: 3/2 closed, monitoring by pressure switch CH 2: 3/2 closed, monitoring by pressure switch
Description:

SDE, category 1, PL c;
PUS, category 3, PL e;
Working valve (CH1): 3/2 closed, electrically actuated, pilot actuated, positive overlap, mechanical spring, monitoring by pressure switch
Operation pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Pilot pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, Video, characteristics of suitable products and a product list of suitable products from Festo.

Document type:
Application Note
Title Version
Circuits Safety Subfunctions Pneumatics

SDE, category 1, PL c;
PUS, category 3, PL e;
Working valve (CH1): 3/2 closed, electrically actuated, pilot actuated, positive overlap, mechanical spring, monitoring by pressure switch
Operation pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Pilot pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, Video, characteristics of suitable products and a product list of suitable products from Festo.

Sicherheits-Teilfunktionen Pneumatik - Schaltung

SDE, Kategorie 1, PL c;
PUS, Kategorie 3, PL e;
Arbeitsventil (CH1): 3/2 entlüftet, elektrisch betätigt, vorgesteuert, positive Überdeckung, mechanische Feder, Überwachung durch Druckschalter
Arbeitsdruck (CH2): 3/2 geschlossen, elektrisch betätigt, vorgesteuert, mechanische Feder, Überwachung durch Druckschalter
Steuerdruck (CH2): 3/2 geschlossen, elektrisch betätigt, vorgesteuert, mechanische Feder, Überwachung durch Druckschalter
Safety Application Note mit einer möglichen Umsetzung der Sicherheits-Teilfunktionen SDE und PUS. Enthalten ist die Grundschaltung, sicherheitsbezogenes Blockdiagramm, Sistema-Projekt, FluidDraw-Projekt, FluidSim-Projekt, Video, Merkmale geeigneter Produkte und eine Produktliste geeigneter Produkte von Festo.