Title:
Safety Subfunctions Pneumatics - Circuit
Subtitle:
SCA, Cat. 3, PL e; CH 1: Proximity switch, cross monitoring; CH 2: Proximity switch, cross monitoring
Description:

SCA, up to Category 3, up to PL e;
Channel 1: Proximity switch, cross monitoring
Channel 2: Proximity switch, cross monitoring
Safety application note with a possible implementation of the safety subfunction SCA. Included are the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products, and a product list of suitable products of Festo.

Document type:
Application Note
Title Version
Safety Subfunctions Pneumatics - Circuit
Sicherheits-Teilfunktionen Pneumatik - Schaltung