Description:
SCA, up to Category 4, up to PL e;
Channel 1: Proximity switch, electromechanical, cross monitoring with short / cross circuit detection
Channel 2: Proximity switch, electromechanical, cross monitoring with short / cross monitoring
Safety application note with a possible implementation of the safety subfunction SCA. Included are the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products, and a product list of suitable products of Festo.