Support Portal

Please select a category on the left or use the search.

Search

Part number

Series

Order code

Description Version
EtherNet/IP IO-Link Integration
EtherNet/IP IO-Link Integration CTEU-EP, CPX-FB36, CPX-CTEL-LK

Controlling IO-Link Devices with Festo EtherNet/IP Products

1.30
7/28/2016
Best Practice: VTSA-F-CB example configurations
Best Practice: VTSA-F-CB example configurations

This file contains sample ID codes of CPX/ VTSA-F-CB valve terminals, including relevant engineering- and design data.

 

  • easy access to sample projects data to get insights to the VTSA-F-CB system
  • quick and easy modification and adaption of ID codes to your use case
Implementing SLS-Safety function based on CMMT-AS X2/X3 encoder evaluation and X10 encoder emulation CMMT-AS-...-S1
Implementing SLS-Safety function based on CMMT-AS X2/X3 encoder evaluation and X10 encoder emulation CMMT-AS-...-S1 CMMT-AS-...-S1

Implementing SLS-Safety function based on CMMT-AS X2/X3 encoder evaluation and X10 encoder emulation CMMT-AS-...-S1

1.10
9/25/2020
Safety Sub-Functions SS1-t: STO, Cat. 4, up to PL e Servo Drive CMMT-AS-…-S1
Safety Sub-Functions SS1-t: STO, Cat. 4, up to PL e Servo Drive CMMT-AS-…-S1 CMMT-AS-…-S1

Safety Sub-Functions SS1-t: STO, Cat. 4, up to PL e

Servo Drive CMMT-AS-…-S1

1.10
6/26/2019
CPX-AP-I with EtherNet/IP; Rockwell Systems and Others
CPX-AP-I with EtherNet/IP; Rockwell Systems and Others CPX-AP-I

How to best commission a CPX-AP-I system on EtherNet/IP. A focus will be on integration with Rockwell Logix systems, but much of the content is also applicable with any EtherNet/IP master.

1.10
5/5/2020
Safety Sub-Functions Pneumatic SET, PUS, Category 1, up to PL c
Safety Sub-Functions Pneumatic SET, PUS, Category 1, up to PL c Pneumatic SET, PUS, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe equilibrium of torque (SET) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains a possible circuit for 5/3 directional control valves and pressure regulators.

1.10
9/19/2019
Safety Sub-Functions Electric Drives SSB with SS1-t, STO, Category 4, up to PL e and SB, Category 1, up to PL c
Safety Sub-Functions Electric Drives SSB with SS1-t, STO, Category 4, up to PL e and SB, Category 1, up to PL c CMMT-AS-…-S1

Application Note for the realization of the safety sub-function safe stopping and blocking (SSB) with the safety sub functions safe stop 1 (SS1) and safe blocking (SB). For the safety sub-function SS1 category 4, up to PL e can bereached; for safety sub-function SB category 1, PL c can be reached. This Application Note contains possible circuits for the servo drive CMMT-AS-…-S1 with holding brake in the servo motor or with an external clamping unit.

1.10
9/19/2019
Safety Sub-Functions Pneumatic SB, PUS, Category 1, up to PL c
Safety Sub-Functions Pneumatic SB, PUS, Category 1, up to PL c Pneumatic SB, PUS, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe blocking (SB) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits together with the safety sub-functions safe torque off (STO) and safe equilibrium of torque (SET).

1.10
9/19/2019
Safety Sub-Functions SS1-t, STO Servo Drive CMMT-AS-…-S1 and CMMT-ST-…-S0, Cross Wiring of Servo Drives
Safety Sub-Functions SS1-t, STO Servo Drive CMMT-AS-…-S1 and CMMT-ST-…-S0, Cross Wiring of Servo Drives CMMT-AS-…-S1; CMMT-ST-…-S0

Application Note for the cross wiring of several servo drives and the realization of the safety sub-functions safe stop 1 (SS1) and safe torque off (STO). Depending on the safe outputs, wiring and fault exclusions is category 3, up to PL d or category 4, up to PL e possible. This Application Note contains possible circuits for the servo drives CMMT-AS-...-S1 and CMMT-ST-…-S0.

1.10
9/17/2019
Safety Sub-Functions SS1-t, STO Servo Drive CMMT-ST-…-S0, Cross Wiring of Servo Drives
Safety Sub-Functions SS1-t, STO Servo Drive CMMT-ST-…-S0, Cross Wiring of Servo Drives CMMT-ST-…-S0

Application Note for the cross wiring of several servo drives and the realization of the safety sub-functions safe stop 1 (SS1) and safe torque off (STO). Depending on the safe outputs, wiring and fault exclusions is category 3, up to PL d or category 4, up to PL e possible. This Application Note contains possible circuits for the servo drive CMMT-ST-…-S0.

1.10
9/17/2019
Safety sub-functions: SS1-t, STO category 3, up to PL d or category 4, up to PL e - Crosswiring
Safety sub-functions: SS1-t, STO category 3, up to PL d or category 4, up to PL e - Crosswiring CMMT-AS-…-S1

Application Note for the cross wiring of several servo drives and the realization of the safety sub-functions safe stop 1 (SS1) and safe torque off (STO). Depending on the safe outputs, wiring and fault exclusions is category 3, up to PL d or category 4, up to PL e possible. This Application Note contains possible circuits for the servo drive CMMT-AS-…-S1.

1.10
9/17/2019
Safety Sub-Functions SS1-t, STO Servo Drive CMMT-ST-…-S0
Safety Sub-Functions SS1-t, STO Servo Drive CMMT-ST-…-S0 With Stepper Motors: SS1-t, STO, Category 3, up to PL e. With EC Motors: STO, Category 3, up to PL d

Application Note for the realization of the safety sub-functions safe stop 1 (SS1) and safe torque off (STO) with category 3 and up to PL e. This Application Note contains possible circuits for the servo drive CMMT-AS-…-S1.

1.0
7/8/2019
Safety Sub-Function STO Servo Drive CMMT-ST-…-S0
Safety Sub-Function STO Servo Drive CMMT-ST-…-S0 With Stepper Motors: STO, Category 3, up to PL e. With EC Motors: STO, Category 3, up to PL d

Application Note for the realization of the safety sub-function safe torque off (STO) with category 3 and up to PL e for stepper motors or category 3 and up to PL d for EC motors. This Application Note contains possible circuits for the servo drive CMMT-ST-…-S0.

1.0
7/8/2019
Safety Sub-Functions Pneumatic
Safety Sub-Functions Pneumatic SDI, PUS, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe direction (SDI) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for monostable 5/2 directional control valves.

1.0
5/14/2019
Safety Sub-Functions Pneumatic
Safety Sub-Functions Pneumatic STO, PUS, SLT, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe torque off (STO), prevention of an unexpected start-up (PUS) and safely-limited torque (SLT) with category 1 and up to PL c. This Application Note contains possible circuits for permanent oder switchable safely-limited torque (SLT).

1.0
5/14/2019
Safety Sub-Functions Pneumatic
Safety Sub-Functions Pneumatic STO, PUS, SLS, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe torque off (STO), prevention of an unexpected start-up (PUS) and safely-limited speed (SLS) with category 1 and up to PL c. This Application Note contains possible circuits for permanent oder switchable safely-limited speed (SLS).

1.0
5/14/2019
Safety Sub-Functions Pneumatic
Safety Sub-Functions Pneumatic SS1, STO, PUS, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe stop 1, time controlled (SS1-t), safe torque off (STO) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for 5/3, 3/2 and 2/2 directional control valves.

1.0
5/14/2019
Safety Sub-Functions Pneumatic
Safety Sub-Functions Pneumatic PUS, Category 1, up to PL c

 

Application Note for the realization of the safety sub-function prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for 5/2 directional control valves.

1.4
5/14/2019
Safety Sub-Functions Pneumatic
Safety Sub-Functions Pneumatic STO, PUS, Category 1, up to PL c

 

Application Note for the realization of the safety sub-functions safe torque off (STO) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for 5/3, 3/2 and 2/2 directional control valves.

1.1
5/14/2019
Safety Sub-Functions Pneumatic
Safety Sub-Functions Pneumatic SSC, PUS, Category 1, up to PL c

 

Application Note for the realization of the safety sub-functions safe stopping and closing (SSC) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for 5/3, 3/2 and 2/2 directional control valves and delockable check valves.

1.1
5/14/2019
Safety Sub-Functions STO, Cat. 4, up to PL e Servo Drive CMMT-AS-…-S1
Safety Sub-Functions STO, Cat. 4, up to PL e Servo Drive CMMT-AS-…-S1 CMMT-AS-...S1

Safety Sub-Functions STO, Cat. 4, up to PL e Servo Drive CMMT-AS-…-S1

1.10
2/26/2019
Replacement of MS6-SV-1/2-E-ASIS-AG by MS6-SV-1/2-E-10V24-AD1
Replacement of MS6-SV-1/2-E-ASIS-AG by MS6-SV-1/2-E-10V24-AD1 MS6-SV-1/2-E-ASIS-AG ; MS6-SV-1/2-E-ASIS-SO-AG

How to replace MS6-SV-E-ASIS with MS6-SV-E-...

1.1
11/30/2018
Safety Sub-Functions in Connection with Motion Terminal VTEM
Safety Sub-Functions in Connection with Motion Terminal VTEM Motion Terminal VTEM

Safety Sub-Functions in Connection with Motion Terminal VTEM

1.33
11/23/2018
Energy management function at adsorption dryer PDAD
Energy management function at adsorption dryer PDAD PDAD-…-…

Application note for use of the energy management function at adsorption dryer PDAD. Explanation, use and layout of purge air regulation for reducing air consumption.

1.10
10/5/2017
Vision Guide
Vision Guide CECC-X

Detailed information about the machine vision capabilities of the CECC-X-M1-MV/-S1

1.10
2/8/2017
Subscribe to RSS