Valve function
3-way proportional pressure control valve
5/2, bistable
2x3/2, open/closed, monostable
3/2, open, monostable
2x3/2, closed, monostable
5/3, pressurized
2/2, closed, monostable
5/3, closed
3/2, closed, monostable
2x3/2, open, monostable
5/2, monostable
5/3, exhausted
KC characters
KC EMC
Valve size
14 mm
10 mm
20 mm
Max. standard nominal flow rate
360 l/min at 10 mm
700 l/min at 20 mm
550 l/min at 14 mm
Pneumatic working port
QS-1/4
QS-4
QS-8
QS-5/16
M7
QS-6
G1/8
QS-3/16
Operating pressure
-0.9 bar ... 10 bar
Electrical actuation
Fieldbus
Max. no. of valve positions
64
Max. no. of pressure zones
17
Electrical I/O system
yes
Ambient temperature
-5 °C ... 50 °C
Degree of protection
IP67
Certification
RCM compliance mark
c UL us - Recognized (OL)
Type code
MPA
Actuation type
Electrical
Flat plate silencer
At one end
Valve terminal type
32
Design
Poppet valve with return spring
Piston gate valve
Pilot air supply port
External
Internal
Valve manifold design
Modular, pneumatic valve sizes can be mixed
Signal status display
LED
Suitability for vacuum
yes
Nominal operating voltage DC
24 V
Permissible voltage fluctuations
+/- 25 %
ATEX category gas
II 3G
Type of ignition protection for gas
Ex nA IIC T4 Gc
Explosion protection certification outside the EU
EPL Gc (BR)
Explosive ambient temperature
-5°C <= Ta <= +50°C
Certificate issuing authority
DNV 15.0193 X
Explosion prevention and protection
Zone 2 (ATEX)
Zone 2 (BR)
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity)
as per EU explosion protection directive (ATEX)
As per EU EMC directive
Corrosion resistance class (CRC)
1 - Low corrosion stress
Storage temperature
-20 °C ... 40 °C
Temperature of medium
-5 °C ... 50 °C
Relative air humidity
Max. 90 % at 40 °C
Note on materials
RoHS-compliant