Analogue module

CPX-4AE-P-D10

560362

Product Documentation

Download Datasheet
Spare parts
Spare parts

Product Documentation

Download Datasheet
Pieces
Configurator is not supported on mobile devices
  • Accessories
  • Technical Data
  • Support / Downloads
Close Technical Data
Show Technical Data
Dimensions W x L x H
(incl. interlinking block)
50 mm x 107 mm x 55 mm
Type code
CPX
No. of inputs
4
Diagnostics
Sensor limit per channel
Limit value violation per channel
Parameterization error
Parameterization
Limit value monitoring per channel diagnostics
Unit of measurement
Sensor limit per channel diagnostics
Diagnostic delay per channel
Hysteresis per module
Measured value smoothing per channel
Relative/differential pressure measurement
Measured variable
4x relative pressure/2x differential pressure
Displayable unit(s)
kPa
psi
mbar
LED indicators
1 group diagnostics
Internal cycle time
5 ms
DC operating voltage range
18 V ... 30 V
Intrinsic current consumption at nominal operating voltage
Typ. 50 mA
Nominal operating voltage DC
24 V
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC)
1 - Low corrosion stress
(when installed)
Storage temperature
-20 °C ... 70 °C
Temperature of medium
0 °C ... 50 °C
Degree of protection
IP67
IP65
Ambient temperature
-5 °C ... 50 °C
Product weight
115 g
Pressure measuring range end value
10 bar
Pressure measuring range initial value
0 bar
Data format
15 bit + sign
Binary representation in mbar, kPa, psi
Pneumatic connection
QS-4
Note on materials
RoHS-compliant
Housing material
PC
PA-reinforced