Flow transmitter

SFTE-1U-M5F-B-2.5K

8058510

Product Documentation

Download Datasheet
Spare parts
Spare parts

Product Documentation

Download Datasheet
Pieces
Configurator is not supported on mobile devices
  • Accessories
  • Technical Data
  • Support / Downloads
Close Technical Data
Show Technical Data
Measured variable
Mass flow rate
Volumetric flow rate
Electrical connection 1, connection technology
Open end
Analog output
1 - 5 V
CE marking (see declaration of conformity)
As per EU EMC directive
As per EU RoHS directive
Certification
RCM compliance mark
Note on materials
RoHS-compliant
Reverse polarity protection
for all electrical connections
Flow direction
Unidirectional
Type code
SFTE
Measuring principle
Thermal
Method of measurement
Heat loss
Short-circuit protection
yes
Housing material
PA-reinforced
Mounting position
Any
Corrosion resistance class (CRC)
2 - Moderate corrosion stress
KC characters
KC EMC
Degree of protection
IP40
Overload protection
Available
Material of cable sheath
TPE-U(PUR)
Symbol
00991853
Electrical connection 1, connection type
Cable
Operating medium
Nitrogen
Compressed air as per ISO 8573-1:2010 [6:4:4]
Type of mounting
With accessories
Line installation
With through-hole
Pneumatic connection
Internal thread M5
Nominal temperature
23 °C
Repetition accuracy in ± %FS
1 %FS
Min. load resistance of voltage output
20 kOhm
Electrical connection 1, number of pins/wires
3
Rise time
3 ms
Flow rate detection range, start value
0 l/min
Cable length
2.5 m
Idle current
≤ 17 mA
Operating pressure
-0.9 bar ... 10 bar
Ambient temperature
0 °C ... 50 °C
DC operating voltage range
22 V ... 26 V
Temperature of medium
0 °C ... 50 °C
Product weight
37 g
Flow rate detection range, end value
1 l/min