Festo uses cookies to improve performance, optimise functionality, analyse access and personalise content and ads. You can disable the use of cookies at any time. For more information, please see our data protection policy and cookie policy.
Core product range
Always in stock worldwide: the core product range for 80% of your applications
Look for the star when selecting products in the catalogue.
For more than 2,200 products worldwide: always in stock, attractively priced and delivered quickly
Fast exhausting after emergency off with the soft-start/quick exhaust valve MS6-SV-E
Show
Hide
Show
Hide
Commissioning
Apply operating pressure p1
Switch on the operating voltage
Self-test starts automatically, then the MS6-SV-E is ready for operation
Apply enable signals. Pressure begins to build up gradually via the flow control valve
Open the main seat at approx. 50% p1
Show
Hide
Adjust pressure build-up
The speed of the gradual pressure build-up is adjusted to p2 via the flow control screw.
Show
Hide
Soft-start 3D view
Show
Hide
Soft-start 2D view
Show
Hide
Exhaust 3D view
Show
Hide
Exhaust 2D view
Show
Hide
Self-test
As soon as the operating pressure p1 has been applied and the operating voltage is switched on, the MS6-SV-E autonomously tests itself for faults. This is indicated by a short blow-off noise at the silencer. The valve is automatically tested once per hour as long as the device is not pressurised.
Show
Hide
Error codes
Four short flashes of the power LED indicate that there are error codes. The error LED then outputs the error code (number of red flashing pulses = error code).
The flashing only stops when the operating voltage is switched off in order to clear the error.
Our soft start/quick exhaust valves MS6-SV cut off the power to critical components in the blink of an eye when an emergency stop is triggered. They also restart the system just as gently and reliably once the problem has been eliminated.
Grid dimension 62 mm
Single-channel exhausting up to Performance Level c and category 1 to EN ISO 13849-1
For reducing pressure quickly and reliably and for building up pressure gradually