Process Automation and Water Management - Learning solutions for basic and advanced training

For tailored advice and product selection/configuration assistance, please contact a sales representative. 30 Process, Flow, and Level Process Control Learning System LV Series 6090-1 and 6090-B, Basic system. The corresponding workbook is entitled “Pressure, Flow, and Level Processes”, sold separately → page 158 Basic system without a bench en fr es 120 V, 60 Hz 588661 588662 588663 220 – 240 V, 50/60 Hz 588664 588665 Note: These systems cannot be sold or delivered in countries that require CE compliance. Basic system with a bench and panels en fr es 120 V, 60 Hz 588655 588656 588657 220 – 240 V, 50/60 Hz 588658 589866 588659 Note: These systems and their components cannot be sold or delivered in countries that require CE compliance. Main components at a glance: – 1x Work surface (stainless steel) – 1x Expanding work Surface (large) – 1x DC power supply – 1x Multimeter – 1x Pumping unit – 1x Column – 2x Hand-operated two-way valve – 1x Solenoid-operated two-way valve – 1x Pressure transmitter – 1x Paddle wheel flow transmitter – 1x Rotameter – 1x Venturi tube – 1x Orifice plate – 2x Pressure gauge (analog, low range) – 1x Float switch – 1x Hose set and accessory kit – 1x I/O interface with LVProSim Only provided with the basic system with bench and panels: – 1x Bench (unassembled, without dressing panels and doors) – 1x Dressing panels (with lockable front door) – 2x Storage/work surface Process Control Training Systems Also required, please order: 1x Rust inhibitor solution 777198 1x Antibacterial solution 8060736 Optional workstation for the basic system without a bench: Bench (unassembled, without dressing panels and doors) 587933 Dressing panels (with lockable front door) 587927 Bench (assembled, without dressing panels and front doors) 587928 Bench (assembled, with dressing panels and lockable front door) 587929 Bench (with dressing panels and lockable doors, unassembled) 587931 Optional equipment: Signal tower 582351 Indicator-light/push-button station 587871 Emergency switch station 582352 Optional measurement equipment: Pressure gauge (digital, high range) 582375 Digital pressure gauge (analog output) 588234 Pressure gauge (analog, medium range) 588235 Pressure gauge (digital, medium range) 588236 Pressure switch (with analog output) 588328 Calibration kit 588416 Calibration kit with pressure modules 588417 Calibration kit (HART) 588418 Calibration kit (HART and FOUNDATION Fieldbus) 588419 Introduction and Fundamentals > Process Control Learning Systems > Variants Basic system with a bench and panels illustrated

RkJQdWJsaXNoZXIy MzE0OTAwNw==