Position transmitter

SDAT-MHS-M50-1L-SA-E-0.3-M8

1531265

Product Documentation

Download Datasheet
Spare parts
Spare parts

Product Documentation

Download Datasheet
Pieces
Configurator is not supported on mobile devices
  • Accessories
  • Technical Data
  • Support / Downloads
Close Technical Data
Show Technical Data
Type code
SDAT
SDAT
Electrical connection 1, type of mounting
Screw-type lock
Screw-type lock
KC characters
KC EMC
Electrical connection 1, connection type
Cable with plug
Cable with plug
Electrical connection 1, connection technology
M8x1 A-coded as per EN 61076-2-104
M8x1 A-coded as per EN 61076-2-104
Electrical connection for input 1, connection pattern
00991171
00991171
Electrical connection 1, number of pins/wires
4
Design
for T-slot
for T-slot
Symbol
00995389
Certification
RCM compliance mark
c UL us - Listed (OL)
RCM compliance mark
c UL us - Listed (OL)
CE marking (see declaration of conformity)
As per EU EMC directive
As per EU EMC directive
Note on materials
Halogen-free
RoHS-compliant
RoHS-compliant
Halogen-free
Measured variable
Position
Position
Measuring principle
Magnetic Hall
Magnetic Hall
Sensing range
0 µm ... 50000 µm
Ambient temperature
-25 °C ... 70 °C
Typical sampling interval
1 ms
Max. travel speed
3 m/s
Displacement resolution
0.05 mm
Repetition accuracy
0.1 mm
Switching output
PNP
PNP
Switching element function
N/C contact/N/O contact switchable
N/C contact/N/O contact switchable
On time
< 2 ms
Switch-off time
< 2 ms
Max. switching frequency
1000 Hz
Max. output current
100 mA
Max. switching capacity DC
2.7 W
Voltage drop
2.5 V
Analog output
4 - 20 mA
4 - 20 mA
Sensitivity
0.32 mA/mm
Typical linearity error in ± mm
±0.25 mm
±0.25 mm
Max. load resistance of current output
500 Ohm
Short-circuit protection
yes
Overload protection
Available
Available
Protocol
IO-Link®
I-Port
I-Port
IO-Link®
IO-Link®, protocol version
Device V 1.1
Device V 1.1
IO-Link®, profile
Smart sensor profile
IO-Link®, function classes
Identification
Teach channel
Diagnostics
Binary data channel (BDC)
Process data variable (PDV)
Process data variable (PDV)
Identification
Diagnostics
Teach channel
IO-Link®, communication mode
COM3 (230.4 kBd)
COM3 (230.4 kBd)
IO-Link®, SIO mode support
Yes
IO-Link®, port class
A
IO-Link®, process data width IN
2 Byte
2 Byte
IO-Link®, process data content IN
4 bit BDC (position monitoring)
12 bit PDV (position measurement)
12 bit PDV (position measurement)
4 bit BDC (position monitoring)
IO-Link®, minimum cycle time
1 ms
1 ms
DC operating voltage range
15 V ... 30 V
Residual ripple
10 %
10 %
Reverse polarity protection
for all electrical connections
for all electrical connections
Connection outlet orientation
Longitudinal
Material of pin contacts
Gold-plated
Copper alloy
Copper alloy
Gold-plated
Connector cable test conditions
Torsional resistance: > 300 000 cycles, ±270°/0.1 m
Cable chain: 5 million cycles, bending radius 28 mm
Flexural strength: as per Festo standard
Cable chain: 5 million cycles, bending radius 28 mm
Torsional resistance: > 300 000 cycles, ±270°/0.1 m
Cable length
0.3 m
Cable characteristic
Suitability for energy chains/robot applications
Suitability for energy chains/robot applications
Color cable sheath
Gray
Gray
Material of cable sheath
TPE-U(PUR)
TPE-U(PUR)
Type of mounting
Screwed tightly
Can be inserted in slot from above
Screwed tightly
Can be inserted in slot from above
Mounting position
Any
Any
Product weight
19 g
Housing material
Polyester
Brass, nickel-plated
PA-reinforced
High-alloy stainless steel
Brass, nickel-plated
PA-reinforced
Polyester
High-alloy stainless steel
Material of union nut
Brass, nickel-plated
Brass, nickel-plated
Film material
Polyester
Polyester
Ready status indication
LED green
Switching status indication
LED yellow
Status indicator
LED red
LED red
Setting options
Pushbutton
IO-Link®
IO-Link®
Pushbutton
Ambient temperature with flexible cable installation
-20 °C ... 70 °C
Degree of protection
IP65
IP68
IP65
IP68