Safety Subfunctions Pneumatics - Circuit
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; CH 1 (working valve): 5/3 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed, monitor
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 05/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 2x3/2 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed, monitoring by
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 2x3/2 exhausted, electrically actuated, pilot actuated, overlap, mechanical spring, monitoring by pressure switch Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 18/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 2 x 3/2 way, monitoring limit switch drive CH 2 (operation pressure): 3/2 closed, monitoring pressure switch CH 2 (p
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 2 x 3/2 exhausted, electrically actuated, overlap, pilot actuated, mechanical spring, limit switch drive Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 18/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Definitions
SDE - Safe De-energization; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe De-energization (SDE)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.50 25/04/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Definitions
SB-p - Safe Blocking with Positive Locking; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe Blocking with Positive Locking (SB-p)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.10 13/03/2025
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - SIL suitability, high demand
SDE - Safe De-energization; PUS - Prevention of Unexpected Start-up
Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics SDE (Safe Deenergization) and PUS (Prevention of Unexpected Start).
|
1.10 21/06/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - SIL suitability, high demand
STO - Safe Torque Off; PUS - Prevention of Unexpected Start-up
Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics STO (Safe Torque Off) and PUS (Prevention of Unexpected Start).
|
1.10 27/06/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - SIL suitability, high demand
SDI - Safe Direction; PUS - Prevention of Unexpected Start-up
Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics STO (Safe Torque Off) and PUS (Prevention of Unexpected Start).
|
1.10 15/02/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - SIL suitability, high demand
PUS - Prevention of Unexpected Start-up
Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-function pneumatics PUS (Prevention of Unexpected Start).
|
1.10 15/02/2024
|
Application NoteFile and language versions
|
|
Safety Subfunktions Pneumatics
Service units
Safety Application Note with information about service units for the use with pneumatic safety subfunctions.
|
1.10 23/04/2024
|