Safety Sub-Functions Pneumatic SB, PUS, Category 1, up to PL c
Pneumatic SB, PUS, Category 1, up to PL c
Application Note for the realization of the safety sub-functions safe blocking (SB) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits together with the safety sub-functions safe torque off (STO) and safe equilibrium of torque (SET).
|
1.10 19/09/2019
|
Application NoteFile and language versions
|
|
Safety Sub-Functions Pneumatic SET, PUS, Category 1, up to PL c
Pneumatic SET, PUS, Category 1, up to PL c
Application Note for the realization of the safety sub-functions safe equilibrium of torque (SET) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains a possible circuit for 5/3 directional control valves and pressure regulators.
|
1.10 19/09/2019
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics
Features of directional control valves
In safety-related pneumatic circuits, certain features of directional control valves should be taken into account. These can result in restrictions, but sometimes also enable interesting solutions.
|
1.10 17/11/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, cat. 1, PL c; PUS, cat. 1, PL c; CH 1: 5/3-way
Safe Torque Off (STO), up to category 1, up to PL c; Prevention of unexpected start-up (PUS), up to category 1, up to PL c; Working valve (CH1): 5/3-way, exhausted, electrically actuated, pilot actuated, mechanical spring; Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is a description, basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.50 22/04/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
PUS, cat. 1, PL c; CH 1: 5/2-way, bistable
Prevention of unexpected start-up (PUS), up to category 1, up to PL c; Channel 1 (working valve): 5/2-way, bistable, electrically actuated, pilot actuated; Safety Application Note with a possible implementation of the safety sub-function PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.40 25/04/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SB-f, up to Cat. 1, up to PL c; PUS, up to Kat. 1, up to PL c; CH 1: Clamping unit
SB-f, up to category 1, up to PL c; PUS, up to category 1, up to PL c; Channel 1: Clamping unit, clamping via spring force, air to release Safety Application Note with a possible implementation of the safety sub-functions SB-f and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 20/03/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SSC, cat. 1, PL c; PUS, cat. 1, PL c; CH 1: 5/3-way
Safe Stopping and Closing (SSC), up to category 1, up to PL c; Prevention of unexpected start-up (PUS), up to category 1, up to PL c; Channel 1 (working valve): 5/3-way, closed, electrically actuated, pilot actuated, mechanical spring; Safety Application Note with a possible implementation of the safety sub-functions SSC and PUS. Included is a description, basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.20 07/05/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SSC, cat. 1, PL c; PUS, cat. 1, PL c; CH 1: piloted check valve; 2 x 3/2-way, closed
Safe Stopping and Closing (SSC), up to category 1, up to PL c; Prevention of unexpected start-up (PUS), up to category 1, up to PL c; Channel 1: piloted check valve; 2 x 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring; Safety Application Note with a possible implementation of the safety sub-functions SSC and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.30 13/05/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SSC, cat. 1, PL c; PUS, cat. 1, PL c; CH 1: 2/2-way; 2 x 3/2-way
Safe Stopping and Closing (SSC), up to category 1, up to PL c; Prevention of unexpected start-up (PUS), up to category 1, up to PL c; Channel 1: 2/2-way, closed; 2 x 3/2-way, exhausting, electrically actuated, pilot actuated, mechanical spring; Safety Application Note with a possible implementation of the safety sub-functions SSC and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.30 14/05/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SSC, up to Cat. 3, up to PL d, PUS, up to Cat. 3, up to PL d; CH 1: piloted check valve, limit switch drive, test cycle CH 2: 5/3 way closed, limit switch drive, test cycle
Safe Stopping (SSC), up to Cat. 3, up to PL d; Prevention of unexpected start-up (PUS), up to Cat. 3, up to PL d; Channel 1: piloted check valve, limit switch drive, test cycle Channel 2: 5/3 way closed, limit switch drive, test cycle Safety Application Note with a possible implementation of the safety sub-functions SSC and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.20 06/10/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SSC, up to Cat. 3, up to PL d, PUS, up to Cat. 3, up to PL d; CH 1: piloted check valve, limit switch drive, test cycle CH 2: 5/3 way closed, limit switch drive, test cycle
Safe Stopping (SSC), up to Cat. 3, up to PL d; Prevention of unexpected start-up (PUS), up to Cat. 3, up to PL d; Channel 1: 2/2 way closed, pneumatic actuated, mechanical spring, limit switch drive, test cycle Channel 2: 5/3 way closed, limit switch drive, test cycle Safety Application Note with a possible implementation of the safety sub-functions SSC and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 11/04/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SDI, up to cat. 1, PL c; PUS, up to cat. 1, PL c; CH 1: 5/2-way, monostable
Safe Direction (SDI), up to category 1, up to PL c;
Prevention of unexpected start-up (PUS), up to category 1, up to PL c; Working valve (CH1): 5/2-way, monostable, electrically actuated, pilot actuated, mechanical spring; Safety Application Note with a possible implementation of the safety sub-functions SDI and PUS. Included is a description, basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.30 31/05/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SDE, cat. 3, PL e; PUS, cat. 3, PL e; CH 1 (working valve): 3/2-way, negative overlap, monitoring pressure switch CH 2 (operation pressure): 3/2-way, monitoring pressure switch
Safe De-Energization (SDE), up to category 3, up to PL e; Prevention of unexpected start-up (PUS), up to category 3, up to PL e; Channel 1 (working valve): 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring, negative overlap, monitoring by pressure switch; Channel 2 (working valve): 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch; Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 13/10/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SDE, cat. 1, PL e; PUS, cat. 3, PL e; CH 1 (working valve): 3/2-way, positive overlap, monitoring pressure switch CH 2 (operation pressure): 3/2-way, monitoring limit switch piston spool
Safe De-Energization (SDE), up to category 1, up to PL c; Prevention of unexpected start-up (PUS), up to category 3, up to PL e; Channel 1 (working valve): 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring, positive overlap, monitoring by pressure switch; Channel 2 (working valve): 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool; Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 13/10/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SDE, cat. 3, PL e; PUS, cat. 3, PL e; CH 1 (working valve): 3/2-way, negative overlap, monitoring pressure switch CH 2 (operation pressure): 3/2-way, monitoring limit switch piston spoo
Safe De-Energization (SDE), up to category 3, up to PL e; Prevention of unexpected start-up (PUS), up to category 3, up to PL e; Channel 1 (working valve): 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring, negative overlap, monitoring by pressure switch; Channel 2 (working valve): 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool; Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 13/10/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
SDE, cat. 4, PL e; PUS, cat. 4, PL e; CH 1: 5/2 monostable, monitoring piston spool CH 2: 5/2 monostable, monitoring piston spool
SDE, up to category 4, up to PL e; PUS, up to category 4, up to PL e; Channel 1 (working valve): 5/2 monostable, electrically actuated, pilot actuated, mechanical spring, limit switch piston spool Channel 2 (working valve): 5/2 monostable, electrically actuated, pilot actuated, mechanical spring, limit switch piston spool Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.20 26/09/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, cat. 1, PL c; PUS, cat. 1, PL c; CH 1 (working valve): 2 x 3/2-way
Safe Torque Off (STO), up to category 1, up to PL c; Prevention of unexpected start-up (PUS), up to category 1, up to PL c; Channel 1 (working valve): 2 x 3/2-way, exhausted, electrically actuated, pilot actuated, mechanical spring; Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.20 19/10/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
Load-voltage Switch-off Valve Terminals
This document provides recommendations on how the load voltage of the valve terminal MPA-FB-VI, MPAL, VTSA-F-CB und VTUG can be safely switched off. It is planned to expand this document with information on other valve terminals.
|
1.50 26/05/2025
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, cat. 1, PL c; PUS, cat. 2, PL d; CH 1 (working valve): 2 x 3/2 Directional control valve, monitoring by limit switch drive; CH 2 (operation pressure): 3/2 closed
Safe Torque Off (STO), up to category 1, up to PL c; Prevention of unexpected startup (PUS), up to category 2, up to PL d; Channel 1 (working valve): 2 x 3/2, closed, monostable, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch drive. Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring. Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.20 03/09/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, cat. 2, up to PL d; PUS, cat. 2, up to PL d; CH 1 (working valve): 2 x 3/2 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed
STO, up to category 2, up to PL d; PUS, up to category 2, up to PL d; Channel 1 (working valve): 2 x 3/2 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch. Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring. Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 01/12/2023
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1: 2 x 3/2 way, monitoring limit switch drive; CH 2: 3/2 way, monitoring pressure switch
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Working valve (CH1): 2 x 3/2, closed, monostable, electrically actuated, pilot actuated, mechanical spring, positive overlap, limit switch drive Operation pressure (CH2):3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring pressure Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 05/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 2 x 3/2 way, monitoring limit switch drive CH 2 (operation pressure): 3/2 closed, monitoring limit switch piston spo
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 2 x 3/2 exhausted, electrically actuated, overlap, pilot actuated, mechanical spring, limit switch drive Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 05/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 5/3 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed, monitoring by p
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 05/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; CH 1 (working valve): 5/3 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed, monitor
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 05/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 2x3/2 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed, monitoring by
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 2x3/2 exhausted, electrically actuated, pilot actuated, overlap, mechanical spring, monitoring by pressure switch Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 18/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Circuit
STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 2 x 3/2 way, monitoring limit switch drive CH 2 (operation pressure): 3/2 closed, monitoring pressure switch CH 2 (p
STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 2 x 3/2 exhausted, electrically actuated, overlap, pilot actuated, mechanical spring, limit switch drive Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.10 18/01/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Definitions
STO - Safe Torque Off; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe Torque Off (STO)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.50 05/12/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Definitions
SDE - Safe De-energization; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe De-energization (SDE)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.50 25/04/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Definitions
PUS - Prevention of Unexpected Start-up (bistable valves)
Safety Application Note with the definition of the safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.40 02/05/2024
|
Application NoteFile and language versions
|
|
Safety Subfunctions Pneumatics - Definitions
SB-f - Safe Blocking with Friction Locking; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe Blocking with Friction Locking (SB-f)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.40 29/05/2024
|
Application NoteFile and language versions
|