Safety Subfunctions Pneumatics - Definitions
SDE - Safe De-energization; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe De-energization (SDE)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.50 25/04/2024
|
Application NoteFile and language versions
|
|
|
Safety Subfunctions Pneumatics - Definitions
PUS - Prevention of Unexpected Start-up (bistable valves)
Safety Application Note with the definition of the safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.40 02/05/2024
|
Application NoteFile and language versions
|
|
|
Safety Subfunctions Pneumatics - Definitions
SB-f - Safe Blocking with Friction Locking; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe Blocking with Friction Locking (SB-f)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.40 29/05/2024
|
Application NoteFile and language versions
|
|
|
Safety subfunctions pneumatics - Definitions
SSC - Safe Stopping and Closing; PUS - Prevention of Unexpected Start-up
Safety subfunctions pneumatics - Definitions
Safety Application Note with the definitions of the safety sub-functions "Safe Stopping and Closing (SSC)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.60 24/11/2025
|
Application NoteFile and language versions
|
|
|
Safety Subfunctions Pneumatics - Definitions
SDI - Safe Direction; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe Direction (SDI)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.30 20/06/2024
|
Application NoteFile and language versions
|
|
|
Safety Subfunctions Pneumatics - Definitions
SB-p - Safe Blocking with Positive Locking; PUS - Prevention of Unexpected Start-up
Safety Application Note with the definitions of the safety sub-functions "Safe Blocking with Positive Locking (SB-p)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.
|
1.10 13/03/2025
|
Application NoteFile and language versions
|
|
|
Safety Subfunctions Pneumatics - SIL suitability, high demand
SDE - Safe De-energization; PUS - Prevention of Unexpected Start-up
Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics SDE (Safe Deenergization) and PUS (Prevention of Unexpected Start).
|
1.10 21/06/2023
|
Application NoteFile and language versions
|
|
|
Safety Subfunctions Pneumatics - SIL suitability, high demand
STO - Safe Torque Off; PUS - Prevention of Unexpected Start-up
Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics STO (Safe Torque Off) and PUS (Prevention of Unexpected Start).
|
1.10 27/06/2023
|
Application NoteFile and language versions
|
|
|
Safety Subfunctions Pneumatics - SIL suitability, high demand
SDI - Safe Direction; PUS - Prevention of Unexpected Start-up
Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics STO (Safe Torque Off) and PUS (Prevention of Unexpected Start).
|
1.10 15/02/2024
|
Application NoteFile and language versions
|
|
|
Safety Subfunctions Pneumatics - SIL suitability, high demand
PUS - Prevention of Unexpected Start-up
Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-function pneumatics PUS (Prevention of Unexpected Start).
|
1.10 15/02/2024
|
Application NoteFile and language versions
|
|
|
Safety subfunctions pneumatics - switching
SDE, cat. 1, PL c; PUS, cat. 1, PL c; CH 1: 3/2-way
Safe De-Energization (SDE), up to category 1, up to PL c; Prevention of unexpected start-up (PUS), up to category 1, up to PL c; Working valve (CH1): 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring; Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim-Project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.40 26/08/2024
|
Application NoteFile and language versions
|
|
|
Safety Subfunktions Pneumatics
Service units
Safety Application Note with information about service units for the use with pneumatic safety subfunctions.
|
1.10 23/04/2024
|
Application NoteFile and language versions
|
|
|
Security white paper for Festo controllers
This document is intended to provide users of Festo control products with an introduction and support on how Festo controllers can be used as securely as possible from the point of view of cyber security.
|
V03 25/05/2023
|
Application NoteFile and language versions
|
|
|
Sicherheits-Teilfunktionen Pneumatik - Schaltung
SDE, cat. 1, PL c; PUS, cat. 3, PL e; CH 1: 3/2 closed, negative overlap, monitoring pressure switch CH 2: 3/2 closed, monitoring limit switch piston spool CH 2: 3/2 closed, monitoring pressure switch
SDE, up to category 1, up to PL c; PUS, up to category 3, up to PL e; Channel 1 (working valve): 3/2 closed, electrically actuated, pilot actuated, negative overlap, mechanical spring, limit switch drive Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim-Project, characteristics of suitable products and a product list of suitable products from Festo.
|
1.20 30/09/2024
|
Application NoteFile and language versions
|
|
|
Tools and repair equipment
Tools and repair equipment, spare parts catalog pages
This information brochure describes the tools and repair accessories required to assemble, maintain and repair Festo products. Here you will find part numbers for tools, lubricants, greases etc.
|
1.10 02/04/2026
|
Application NoteFile and language versions
|