Support Portal

Please select a category on the left or use the search.

Search

Part number

Series

Order code

Description Version
Special Provisions for the Use of Festo Security Advisories

The following special provisions for the use of Festo Security Advisories (the "Special Provisions") apply in addition to and partially amend the Festo

31/03/2025
Circuits Safety Subfunctions Pneumatics STO, up to category 1, up to PL c; PUS, up to category 2, up to PL d; CH 1 (working valve): 5/3 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed

STO, up to category 1, up to PL c;
PUS, up to category 2, up to PL d;
Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch.
Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring.
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.20
01/12/2023
Circuits Safety Subfunctions Pneumatics STO, cat. 1, PL c; PUS, cat. 2, PL d; CH 1: 5/3 way valve, monitoring by limit switch drive; OTE: 3/2-way valve, closed

Safe Torque Off (STO), up to category 1, up to PL c;
PUS, up to category 2, up to PL d;
Channel 1 (working valve): 5/3-way valve, exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch drive.
Output test channel (operation pressure): 3/2-way valve, closed, electrically actuated, pilot actuated, mechanical spring.
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.

1.30
28/08/2024
Circuits Safety Subfunctions Pneumatics STO, cat. 1, PL c; PUS, cat. 3, PL e; working valve (CH1): 5/3 way, monitoring by limit switch drive; operation pressure (CH2): 3/2 closed, monitoring pressure switch pilot pressure (CH2): 3/2 closed,

STO, category 1, PL c;
PUS, category 3, PL e;
working valve (CH1): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, limit switch drive
operation pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
pilot pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.

1.50
22/07/2024
Circuits Safety Subfunctions Pneumatics STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 5/3 Directional control valve, monitoring by limit switch drive; CH 2 (operation pressure): 3/2 closed, monitoring p

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch drive
Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.30
23/11/2023
Circuits Safety Subfunctions Pneumatics STO, cat. 1, PL c; PUS, cat. 3, PL e; CH 1 (working valve): 5/3 Directional control valve, monitoring by pressure switch CH 2 (operation pressure): 3/2 closed, monitoring limit switch piston spool CH

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, limit switch drive
Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool
Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
14/09/2022
Circuits Safety Subfunctions Pneumatics PUS, cat. 3, up to PL e; working valve (CH 1): 5/2-way, bistable, monitoring by limit switch drive operation pressure (CH2): 3/2 closed, monitoring limit switch piston spool pilot pressure (CH2): 3/2

PUS, category 3, up to PL e;
working valve (CH 1): 5/2-way bistable, electrically actuated, pilot actuated, limit switch drive
operation pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool
pilot pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-function PUS for bistable valves. Included is a description, basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.

1.30
22/07/2024
Circuits Safety Subfunctions Pneumatics SB-f, up to Cat. 3, up to PL d; PUS, up to Kat. 3, up to PL d; CH 1: Clamping unit; static brake test CH 2: Clamping unit; static brake test

SB-f, up to category 1, up to PL c;
PUS, up to category 1, up to PL c;
Channel 1: Clamping unit, clamping via spring force, air to release; 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring; static brake test
Channel 2: Clamping unit, clamping via spring force, air to release; 3/2-way, closed, electrically actuated, pilot actuated, mechanical spring; static brake test
Safety Application Note with a possible implementation of the safety sub-functions SB-f and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.20
12/02/2025
Circuits Safety Subfunctions Pneumatics SDE, cat. 1, PL c; PUS, cat. 3, PL e; CH 1: 3/2 closed, positive overlap, monitoring by pressure switch CH 2: 3/2 closed, monitoring by pressure switch CH 2: 3/2 closed, monitoring by pressure switch

SDE, category 1, PL c;
PUS, category 3, PL e;
Working valve (CH1): 3/2 closed, electrically actuated, pilot actuated, positive overlap, mechanical spring, monitoring by pressure switch
Operation pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Pilot pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, Video, characteristics of suitable products and a product list of suitable products from Festo.

1.40
19/09/2024
Circuits Safety Subfunctions Pneumatics SDE, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 3/2 closed, positive overlap, monitoring by pressure switch CH 2 (operation pressure): 3/2 closed, monitoring limit

SDE, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 3/2 closed, electrically actuated, pilot actuated, positive overlap, mechanical spring, limit switch drive
Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool
Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
13/10/2023
Circuits Safety Subfunctions Pneumatics SDE, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 3/2 closed, positive overlap, monitoring by pressure switch CH 2 (operation pressure): 3/2 closed, monitoring limit

SDE, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 3/2 closed, electrically actuated, pilot actuated, positive overlap, mechanical spring, limit switch drive
Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool
Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product

1.10
13/10/2023
Circuits Safety Subfunctions Pneumatics SDE, up to cat. 3, up to PL e; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 3/2 closed, negative overlap, monitoring by pressure switch CH 2 (operation pressure): 3/2 closed, monitoring limit

SDE, up to category 3, up to PL e;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 3/2 closed, electrically actuated, pilot actuated, negative overlap, mechanical spring, limit switch drive
Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool
Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
13/10/2023
Circuits Safety Subfunctions Pneumatics SDI, up to category 1, up to PL c; PUS, up to category 3, up to PL e; CH 1 (working valve): 5/2 directional control valve, monostable, monitoring by limit switch drive;

CH 2 (operation pressure): 3/2 directional control valve, closed, monitoring pressure switch
CH 2 (pilot pressure): 3/2 directional control valve, closed, monitoring pressure switch

 

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 5/2 directional control valve, monostable, electrically actuated, pilot actuated, mechanical spring, limit switch drive
Channel 2 (operation pressure ): 3/2 directional control valve, monostable, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Channel 2 (pilot pressure ): 3/2 directional control valve, monostable, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions SDI and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.30
25/08/2025
Circuits Safety Subfunctions Pneumatics STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; CH 1 (working valve): 2x3/2 Directional control valve, monitoring by limit switch drive; CH 2 (operation pressure): 3/2 closed, mo

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 2x3/2 exhausted, electrically actuated, pilot actuated, mechanical spring, limit switch drive
Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
05/01/2024
Circuits Safety Subfunctions Pneumatics Switch-off single valves

In this Safety Application Note, possible circuits for the safe switch-off of individual valves in the various categories and PL are given.

1.20
20/05/2025
Circuits Safety Subfunctions Pneumatics PUS, cat. 3, PL e; working valve (CH 1): 5/2-way, monitoring by limit switch drive; operation pressure ( CH 2): 3/2 closed, monitoring pressure switch

PUS, category 3, PL e;
working valve (CH1): 5/2 bistable, electrically actuated, pilot actuated, monitoring by limit switch drive
operation pressure (CH2): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-function PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.

V1.10
19/07/2024
Circuits Safety Subfunctions Pneumatics PUS, up to cat. 2, up to PL d; CH 1 (working valve): 5/2-way, bistable, monitoring by limit switch drive OTE (operation pressure): 3/2 closed

PUS, category 2, PL d;
Channel 1 (working valve): 5/2 bistable, electrically actuated, pilot actuated, monitoring by limit switch drive
Output of test equipment OTE (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring
Safety Application Note with a possible implementation of the safety sub-function PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
21/08/2024
Circuits Safety Subfunctions Pneumatics "SDE, cat. 3, PL e; PUS, cat. 3, PL e; SB: MS6-SV-…-D"

SDE, up to category 4, up to PL e;
PUS, up to category 4, up to PL e;
Subsystem: MS6-SV-...-D Soft-start / quick-exhaust valve
Safety Application Note with a possible implementation of the safety sub-functions SDE and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.20
27/11/2024
Circuits Safety Subfunctions Pneumatics ISO 13849 STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 5/3 Directional control valve, monitoring by limit switch drive; CH 2 (operation pressure): 3/2 closed, monitoring l

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch drive
Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.20
13/10/2023
EMC - Checklist General

A checklist to avoid EMC trouble

 

1.10
03/03/2023
Festo Sustainability Report 2024 Festo_Sustainability Report_2024

Festo Sustainability Report 2024

1.10
03/07/2025
Recommended circuits for safety sub-functions Recommended circuits for safety sub-functions

A page with links to the recommended application notes with definitions and circuits for the pneumatic safety sub-functions in the Festo Support Portal.

1.20
07/05/2024
Safety Subfunctions Electrical Drives Safety Subfunction STO: Cat. 1, PL c and Cat. 4, PL e

Safety subfunction STO, up to category 1, up to PL c;
Channel 1: Switch-off supply by conductor.
Safety subfunction STO, up to category 4, up to PL e;
Channel 1 and 2: Switch-off supply by conductor,
Safety Application Note with a possible implementation of the safety sub-functions STO. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project.

1.10
17/11/2023
Safety Sub-Functions Pneumatic STO, PUS, Category 1, up to PL c

 

Application Note for the realization of the safety sub-functions safe torque off (STO) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for 5/3, 3/2 and 2/2 directional control valves.

1.1
14/05/2019
Safety Sub-Functions Pneumatic SSC, PUS, Category 1, up to PL c

 

Application Note for the realization of the safety sub-functions safe stopping and closing (SSC) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for 5/3, 3/2 and 2/2 directional control valves and delockable check valves.

1.1
14/05/2019
Safety Sub-Functions Pneumatic PUS, Category 1, up to PL c

 

Application Note for the realization of the safety sub-function prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for 5/2 directional control valves.

1.4
14/05/2019
Safety Sub-Functions Pneumatic SS1, STO, PUS, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe stop 1, time controlled (SS1-t), safe torque off (STO) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for 5/3, 3/2 and 2/2 directional control valves.

1.0
14/05/2019
Safety Sub-Functions Pneumatic STO, PUS, SLS, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe torque off (STO), prevention of an unexpected start-up (PUS) and safely-limited speed (SLS) with category 1 and up to PL c. This Application Note contains possible circuits for permanent oder switchable safely-limited speed (SLS).

1.0
14/05/2019
Safety Sub-Functions Pneumatic STO, PUS, SLT, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe torque off (STO), prevention of an unexpected start-up (PUS) and safely-limited torque (SLT) with category 1 and up to PL c. This Application Note contains possible circuits for permanent oder switchable safely-limited torque (SLT).

1.0
14/05/2019
Safety Sub-Functions Pneumatic SDI, PUS, Category 1, up to PL c

Application Note for the realization of the safety sub-functions safe direction (SDI) and prevention of an unexpected start-up (PUS) with category 1 and up to PL c. This Application Note contains possible circuits for monostable 5/2 directional control valves.

1.0
14/05/2019
Show 30 more results ...