Safety Subfunctions Pneumatics - Circuit Load-voltage Switch-off Valve Terminals

This document provides recommendations on how the load voltage of the valve terminal MPA-FB-VI, MPAL, VTSA-F-CB, VTUG and VTUX can be safely switched off. It is planned to expand this document with information on other valve terminals.

1.50
23/04/2026
Safety Subfunctions Pneumatics - Circuit STO, cat. 1, PL c; PUS, cat. 2, PL d; CH 1 (working valve): 2 x 3/2 Directional control valve, monitoring by limit switch drive; CH 2 (operation pressure): 3/2 closed

Safe Torque Off (STO), up to category 1, up to PL c;
Prevention of unexpected startup (PUS), up to category 2, up to PL d;
Channel 1 (working valve): 2 x 3/2, closed, monostable, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch drive.
Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring.
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, FluidSim project, characteristics of suitable products and a product list of suitable products from Festo.

1.20
03/09/2024
Safety Subfunctions Pneumatics - Circuit STO, cat. 2, up to PL d; PUS, cat. 2, up to PL d; CH 1 (working valve): 2 x 3/2 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed

STO, up to category 2, up to PL d;
PUS, up to category 2, up to PL d;
Channel 1 (working valve): 2 x 3/2 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch.
Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring.
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
01/12/2023
Safety Subfunctions Pneumatics - Circuit STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1: 2 x 3/2 way, monitoring limit switch drive; CH 2: 3/2 way, monitoring pressure switch

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Working valve (CH1): 2 x 3/2, closed, monostable, electrically actuated, pilot actuated, mechanical spring, positive overlap, limit switch drive
Operation pressure (CH2):3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring pressure
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
05/01/2024
Safety Subfunctions Pneumatics - Circuit STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 2 x 3/2 way, monitoring limit switch drive CH 2 (operation pressure): 3/2 closed, monitoring limit switch piston spo

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 2 x 3/2 exhausted, electrically actuated, overlap, pilot actuated, mechanical spring, limit switch drive
Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by limit switch piston spool
Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
05/01/2024
Safety Subfunctions Pneumatics - Circuit STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 5/3 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed, monitoring by p

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
05/01/2024
Safety Subfunctions Pneumatics - Circuit STO, up to category 1, up to PL c; PUS, up to category 3, up to PL e; CH 1 (working valve): 5/3 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed, monitor

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 5/3 exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
05/01/2024
Safety Subfunctions Pneumatics - Circuit STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 2x3/2 Directional control valve, monitoring by pressure switch; CH 2 (operation pressure): 3/2 closed, monitoring by

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 2x3/2 exhausted, electrically actuated, pilot actuated, overlap, mechanical spring, monitoring by pressure switch
Channel 2 (operation pressure): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
18/01/2024
Safety Subfunctions Pneumatics - Circuit STO, up to cat. 1, up to PL c; PUS, up to cat. 3, up to PL e; CH 1 (working valve): 2 x 3/2 way, monitoring limit switch drive CH 2 (operation pressure): 3/2 closed, monitoring pressure switch CH 2 (p

STO, up to category 1, up to PL c;
PUS, up to category 3, up to PL e;
Channel 1 (working valve): 2 x 3/2 exhausted, electrically actuated, overlap, pilot actuated, mechanical spring, limit switch drive
Channel 2 (operation pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Channel 2 (pilot pressure ): 3/2 closed, electrically actuated, pilot actuated, mechanical spring, monitoring by pressure switch
Safety Application Note with a possible implementation of the safety sub-functions STO and PUS. Included is the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.20
23/07/2026
Safety Subfunctions Pneumatics - Circuit STO, up to Cat. 4, up to PL e; PUS, up to Cat. 4, up to PL e; Channel 1: 6/2-way valve, monitoring limit switch piston spool; CH 2: 6/2-way valve, monitoring limit siwtch piston spool;

Working valve: any:

STO, up to Category 4, up to PL e;
PUS, up to Category 4, up to PL e;
Channel 1: 6/2 exhausted, electrically actuated, negative lap, pilot-operated, mechanical spring, monitored by limit switch piston spool
Channel 2: 6/2 vented, electrically actuated, pilot-operated, mechanical spring, monitored by limit switch piston spool
Safety application note with a possible implementation of the safety subfunctions STO and PUS using the VOFT valve block. Included are the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products, and a product list of suitable products of Festo.

1.10
18/03/2026
Safety Subfunctions Pneumatics - Circuit STO, up to Cat. 1, up to PL c; PUS, up to Cat. 1, up to PL c; Channel 1: 6/2-way valve, monitoring limit switch piston spool; Working valve: any

STO, up to Category 1, up to PL c;
PUS, up to Category 1, up to PL c;
Channel 1: 6/2 exhausted, electrically actuated, pilot-operated, mechanical spring, monitored by limit switch piston spool
Safety application note with a possible implementation of the safety subfunctions STO and PUS using the VOFT valve block. Included are the basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products, and a product list of suitable products of Festo.

1.10
18/03/2026
Safety Subfunctions Pneumatics - Circuit Test cycle for SSC with limit switches on the drive

Safety Application Note with a test cycle as diagnosis for the safety sub-function SSC when 5/3-way valves, closed, or using pilot operated check valves.

1.10
17/08/2026
Safety Subfunctions Pneumatics - Circuit SC, cat. 1, PL c; CH 1: 5/4-way valve VUVX-P54E

Safe Closing (SC), up to category 1, up to PL c;
Working valve (CH1): 5/4-way, exhausted, electrically actuated, pilot actuated, mechanical spring;
Safety Application Note with a possible implementation of the safety sub-functions SC. Included is a description, basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
19/08/2026
Safety Subfunctions Pneumatics - Circuit SC, cat. 3, PL d; CH 1: 5/4-way valve VUVX-P54E, monitoring limit switches drive; CH 2: 3/2-way valve, monitoring pressure switch

Safe Closing (SC), up to category 3, up to PL d;
Working valve (CH1): 5/4-way, exhausted, electrically actuated, pilot actuated, mechanical spring, monitoring limit switches drive;
Operation pressure (CH2): 3/2-way valve, closed, electrically actuated, pilot actuated, mechanical spring, monitoring pressure switch;
Safety Application Note with a possible implementation of the safety sub-functions SC. Included is a description, basic circuit, safety-related block diagram, Sistema project, FluidDraw project, characteristics of suitable products and a product list of suitable products from Festo.

1.10
19/08/2026
Safety Subfunctions Pneumatics - Definitions SDE - Safe De-energization; PUS - Prevention of Unexpected Start-up

Safety Application Note with the definitions of the safety sub-functions "Safe De-energization (SDE)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.

1.50
25/04/2024
Safety Subfunctions Pneumatics - Definitions BT-s - Static Brake Test

Safety Application Note with the definitions of the monitoring function

"Static Brake Test (BT-s)" for pneumatic circuits and the possible results. For practical implementation, additional notes are given which should be observed depending on the application.

1.20
26/08/2026
Safety Subfunctions Pneumatics - Definitions SB-p - Safe Blocking with Positive Locking; PUS - Prevention of Unexpected Start-up

Safety Application Note with the definitions of the safety sub-functions "Safe Blocking with Positive Locking (SB-p)" and the related safety sub-function "Prevention of Unexpected Start (PUS)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.

1.10
13/03/2025
Safety Subfunctions Pneumatics - Definitions SC - Safe Closing

Safety Application Note with the definitions of the safety sub-function "Safe Closing (SC)" for pneumatic circuits and their safe condition. For practical implementation, additional notes are given which should be observed depending on the application.

1.10
19/08/2026
Safety Subfunctions Pneumatics - SIL suitability, high demand SDE - Safe De-energization; PUS - Prevention of Unexpected Start-up

Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics SDE (Safe Deenergization) and PUS (Prevention of Unexpected Start).

1.10
21/06/2023
Safety Subfunctions Pneumatics - SIL suitability, high demand STO - Safe Torque Off; PUS - Prevention of Unexpected Start-up

Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics STO (Safe Torque Off) and PUS (Prevention of Unexpected Start).

1.10
27/06/2023
Safety Subfunctions Pneumatics - SIL suitability, high demand SDI - Safe Direction; PUS - Prevention of Unexpected Start-up

Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-functions pneumatics STO (Safe Torque Off) and PUS (Prevention of Unexpected Start).

1.10
15/02/2024
Safety Subfunctions Pneumatics - SIL suitability, high demand PUS - Prevention of Unexpected Start-up

Document contains a possible evaluation of the SIL suitability of directional control valves as an element according to IEC 61508, High Demand Mode for safety sub-function pneumatics PUS (Prevention of Unexpected Start).

1.10
15/02/2024
Safety Subfunktions Pneumatics Service units

Safety Application Note with information about service units for the use with pneumatic safety subfunctions.

1.10